Diagnostic accuracy of compression ultrasonography for the detection of asymptomatic deep venous thrombosis in medical patients--the TADEUS project.

Abstract : We assessed the accuracy of venous compression ultrasonography (CUS) for the detection of asymptomatic deep vein thrombosis in 122 consecutive patients, with a mean age of 69 years, who were hospitalised in an internal medicine unit. All included patients had CUS within 48 h of admission. Twelve out of 17 patients with a positive CUS underwent phlebography, as the others withdrew their consent, whereas the remaining 105 patients with a negative serial CUS testing were clinically followed-up at 3 months. We found that CUS had a sensitivity and a specificity of respectively 1 (95% CI, 0.73 to 1) and 1 (95% CI, 0.96 to 1) for the detection of asymptomatic deep vein thrombosis. Kappa-coefficients for intra-observer and inter-observer agreements were respectively 0.88 and 0.56. We concluded that venous compression ultrasonography, performed as described, fulfils requirements of a screening test that could be available for prophylactic clinical trials or epidemiological researches.
Document type :
Journal articles
Complete list of metadatas

https://hal.univ-brest.fr/hal-00722340
Contributor : Ghislaine Calvez <>
Submitted on : Wednesday, August 1, 2012 - 1:07:48 PM
Last modification on : Wednesday, September 16, 2020 - 5:04:36 PM

Identifiers

  • HAL Id : hal-00722340, version 1
  • PUBMED : 11521998

Collections

Citation

Luc Bressollette, Michel Nonent, Emmanuel Oger, Jean-François Garcia, Pascal Larroche, et al.. Diagnostic accuracy of compression ultrasonography for the detection of asymptomatic deep venous thrombosis in medical patients--the TADEUS project.. Thrombosis and Haemostasis, Schattauer, 2001, 86 (2), pp.529-33. ⟨hal-00722340⟩

Share

Metrics